Knee Range Of Motion Measurements

How to Measure Knee ROM:

Reliability:

  • Intra-examiner
    • Passive Flexion and Extension
      • Rothstein et al (Phys Ther. 63:1611; 1983); Three Goniometers; ICC's of Flexion Extension
        • Metal .97 ; .96
        • Large Plastic .99 ; .91
        • Small Plastic .99 .97
      • Watkins et al (Phys Ther 71:90; 1991) : Standard Goniomter; ICC's
        • Flexion .99; Extension .98
      • Hayes et al (Phys Ther 74:697; 1994); Universal Goniometer; ICC's
        • Flexion .95-.96; Extension .71-.86
    • Active Flexion and Extension
      • Clapper and Wolf (Phys Ther 68:215 1988); Standard Goniometer; ICC's
        • Flexion .95; Extension .85
      • Brosseau et al (Physiother Res Int 2:150 1997); Universal Goniometer; ICC's
        • Flexion.86-.97
  • Inter-examiner
    • Passive Flexion and Extension
      • Gogia et al (Phys Ther 67:192 1987); Standard Goniometer; ICC's
        • Flexion .99
      • Watkins et al (Phys Ther 71:90; 1991); ICC's
        • Flexion .90; Extension .86 (Standard Goniometer)
        • Flexion .83; Extension .82 (Visual Estimation)
      • Fritz et al (Phys Ther 78:1046; 1998); Standard Goniometer; ICC's
        • Flexion .97; Extension .94 (Involved knee)
        • Flexion .80; Extension .72 (Uninvolved knee)
    • Active Flexion and extension
      • Brosseau et al (Physiother Res Int 2:150 1997); Universal Goniometer; ICC's
        • Flexion: .62-1.0

*