Knee Range Of Motion Measurements
How to Measure Knee ROM:
Reliability:
- Intra-examiner
- Passive Flexion and Extension
- Rothstein et al (Phys Ther. 63:1611; 1983); Three Goniometers; ICC's of Flexion Extension
- Metal .97 ; .96
- Large Plastic .99 ; .91
- Small Plastic .99 .97
- Watkins et al (Phys Ther 71:90; 1991) : Standard Goniomter; ICC's
- Flexion .99; Extension .98
- Hayes et al (Phys Ther 74:697; 1994); Universal Goniometer; ICC's
- Flexion .95-.96; Extension .71-.86
- Rothstein et al (Phys Ther. 63:1611; 1983); Three Goniometers; ICC's of Flexion Extension
- Active Flexion and Extension
- Clapper and Wolf (Phys Ther 68:215 1988); Standard Goniometer; ICC's
- Flexion .95; Extension .85
- Brosseau et al (Physiother Res Int 2:150 1997); Universal Goniometer; ICC's
- Flexion.86-.97
- Clapper and Wolf (Phys Ther 68:215 1988); Standard Goniometer; ICC's
- Passive Flexion and Extension
- Inter-examiner
- Passive Flexion and Extension
- Gogia et al (Phys Ther 67:192 1987); Standard Goniometer; ICC's
- Flexion .99
- Watkins et al (Phys Ther 71:90; 1991); ICC's
- Flexion .90; Extension .86 (Standard Goniometer)
- Flexion .83; Extension .82 (Visual Estimation)
- Fritz et al (Phys Ther 78:1046; 1998); Standard Goniometer; ICC's
- Flexion .97; Extension .94 (Involved knee)
- Flexion .80; Extension .72 (Uninvolved knee)
- Gogia et al (Phys Ther 67:192 1987); Standard Goniometer; ICC's
- Active Flexion and extension
- Brosseau et al (Physiother Res Int 2:150 1997); Universal Goniometer; ICC's
- Flexion: .62-1.0
- Brosseau et al (Physiother Res Int 2:150 1997); Universal Goniometer; ICC's
- Passive Flexion and Extension
*